Image

Simple Gas Clip (SCG) ZONE 0/20

Whether it’s the hottest environment or the coldest, our Single Gas Clip is designed and tested to provide worker safety in the harshest working conditions. At Gas Clip Technologies, we enhance customer safety by using the latest technology. We test 100% of our portable gas detectors, not just a random sample of units. That’s why we can offer a low cost of ownership on our gas detectors. There are no hidden service charges, no maintenance fees– just reliable units that will help your facility workers and contractors do their jobs safely, productively and cost effectively.

For unmatched safety, reliability and productivity, choose the world’s most advanced single gas detector, the Single Gas Clip.

Be sure to compare these features to our Multi Gas Clip and Single Gas Clip Plus to find the right product for your current application.

Loud alarm

Visual, vibrating & audible

Works in loud environments

No matter how noisy

IP 67

Certified

Core Features
  • Unmatched sensor reliability for H2S, CO, & O2
  • Adjustable alarm set points
  • Real-time gas reading capability
  • 0.1 ppm resolution for H2S sensor and display
  • Two-way IR communication for event downloads, bump tests & updates
  • Programmable unit identification
  • Calibration optional
  • “Bump check” confirmation/identification
Physical Characteristics
  • 3.4 H x 1.9 W x 1.1 D in. (85.5 x 48 x 29 mm.)
  • 2.7 oz. (76g)
  • 5% to 95% RH (non-condensing)
  • H2S: -40°C to +50°C/-40°F to +122°F
  • CO: -40°C to +50°C/-40°F to +122°F
  • O2: -35°C to +50°C/-31°F to +122°F
  • EMC Directive 2004/108/EC
  • Rated IP67
  • High viewing angle Alphanumeric Liquid Crystal Display
Software Features
  • Visual, vibrating & audible (minimum 95 dB) Detector life countdown (EOL), Low, High & Over limit (OL) Alerting
  • Logging for 25 Events - newer events replace older events
  • Full function self-test upon activation and every 20 hours and continuous automatic battery tests
Versions
  • Single Gas Clip H2S (SGC-H) Measuring range: 0-100 ppm Low alarm limit: 10 ppm - High alarm limit: 15 ppm
  • Single Gas Clip CO (SGC-C) Measuring range: 0-300 ppm Low alarm limit: 35 ppm - High alarm limit: 200 ppm
  • Single Gas Clip O2 (SGC-O) Measuring range: 0-30% by vol. Low alarm limit: 19.5% - High alarm limit: 23.5%
  • NOTE Alarm set points listed above are factory default. These set points can be changed using the GCT IR Link (sold separately).
Image
3204TP Spijkenisse
the Netherlands
info@atexglobal.nl
+31 (0)10 273 2243